Oliver Mercer North Dunn - FRO Pretreatment Plant

After a competitive bid Wigen Water was awarded the project with Toray UF Modules


Oliver Mercer North Dunn - FRO Pretreatment Plant
Contact


Operation Since: 2012/04


Location: 20 km northwest from Beulah, ND, USA


Plant Capacity: 22,918 m3/d (6.1 MGD)


Application: Drinking Water


Engineer: Bartlett & West


O & M: Wigen Water Technologies


Other Remark: After a competitive bid Wigen Water was awarded the

project with Toray UF Modules


Pre-treatment: 200 micron mesh prefilter Process flow 


Membrane Model: 1st Stage HFS-2020 (52 pcs. x 5 trains = 260 pcs.) 2nd Stage HFS-2020 (16 pcs. x 2 trains = 32 pcs.)

Feed Water Quality: Feed source is Lake Sakakawea with feed temperatures 1-20 deg C, turbidity 1-10 NTU and TOC from 3.5 – 4.0 mg/L.


Required Quality: UF Filtrate turbidity is always < 0.1 NTU and normally < 0.02 NTU


Required Quality: UF Filtrate turbidity is always < 0.1 NTU and normally < 0.02 NTU